Other Countries
Pricelist request
Copyright
Group Head Quarters • English
Ethics Policy
Home • Products • FansCentrifugal fans • KCF
I04  •  Centrifugal fansdownloads

KCF

Single inlet centrifugal fan.

Application

  • Used for the extraction of industrial cooker hoods for duties up to 9000m3/h

Composition

  • Double skin housing with 40mm mineral wool and wide-opening door for easy access for cleaning.
  • Circular in-and outlet
  • Grease and condensation drain

Impeller

  • Backward inclined blades impeller

Motor

  • Supply: 230Vac 1ph, 400Vac 3ph for KCF 400 D4
  • Motor with overheat protection en speed controllable
  • Insulation class F – Protection class IP55

Accessories

  • Speed controller type BTRNTK
  • Fitting clamp type BMK
  • Motor protection cover MPG KCF

Other available products

  • KCF-F equipped with a motor with integrated frequency inverter.

Text for tender

  • Single inlet centrifugal fan. Used for the extraction of industrial cooker hoods for duties up to 6700m3/h.
  • ATC type KCF

Order example

  • KCF 200 E2

 

Explanation: 

KCF = Type of fan

E = single phase, 230V

2 = 2 pole

Articles

Article number Type Diameter [mm] Voltage [V] Speed [rpm]
  I040400000200KCF 200 E2 200 1 x 230 2770
  I040400000250KCF 250 E2 250 1 x 230 2770
  I040400000315KCF 315 E2 315 1 x 230 2720
  I040400000316KCF 315 E2L 315 1 x 230 2860
  I040400000355KCF 355 E4 355 1 x 230 1350
  I040400000400KCF 400 E4 400 1 x 230 1350
  I040400000401KCF 400 D4 400 3 x 400 1350

Air performance data

Q [m3/h]

100 Pa

200 Pa

300 Pa

400 Pa

500 Pa

600 Pa

700 Pa

800 Pa

KCF 200 E2

1600 1480 1320 1170 970 700 - -

KCF 250 E2

2500 2350 2250 2100 1850 1700 1400 1200

KCF 315 E2

3500 3300

3100

2800 2600 2400 2000 1600

KCF 315 E2L

4400

4250

4070

3880

3680

3500

3270

3050

KCF 355 E4

4700 4400 3800 3200 2250

-

- -

KCF 400 E4

6700

6200

5600

4900 4200 3200

-

-

KCF 400 D4

9000

8500

8000

7460

6820

6180

5360

3950

Pressure Curve

Pressure curve

Technical data

U [V]

P [W]

I [A]

SCT

ŋt [%]

tm [°C]

tu [°C]

to [°C]

n [rpm]

Lwa [db(A)]

Lwa 5 Lwa 6

Lwa 2

KCF 200 E2

1 x 230

370 2.60

BTRNTK 1-35

44.80 80 80 -25 2843 83 83

70

KCF 250 E2

1 x 230

620 4

BTRNTK 1-50

48

120

75

-25 2843 86 87

66

KCF 315 E2

1 x 230

940 5.50

BTRNTK 1-75

53 80 50 -25 2818 87 85

72

KCF 315 E2L

1 x 230

1380

8.1

BTRNTK 1-100

51.5

120

60

-25

2910

91

90

76

KCF 355 E4

1 x 230

820

4.50

BTRNTK 1-50

48

80

55

-25

1353

80

80

73

KCF 400 E4

1 x 230

1320

7.50

BTRNTK 1-75

54

120

50

-25

1391

83

85

74

KCF 400 D4

3 x 400

2100

4.5

BTRNTK 4-60

53

120

70

-30

1340

82

84

73

Pressure curve

SCT = transformer controller

ŋt = maximum total efficiency

tm = maximum air temperature

tu = maximum ambient temperature

to = minimum operating temperature

Lwa 2 = Casing sound power level

Lwa 5 = Sound power level @inlet

Lwa 6 = Sound power level @outlet

The sound power levels are measured according to DIN 45635 part 2 & 38

Attention

3 positions possible. Vertical discharge available on stock.

Dimensions

L [mm]

W [mm]

H [mm]

kg

KCF 200 E2

287

484 484 29

KCF 250 E2

287

584 584 40

KCF 315 E2

336

684 684 50

KCF 315 E2L

336

684 684 54

KCF 355 E4

386

784 784

63

KCF 400 E4

436

884

884

70

KFC 400 D4

436

884

884

100

I04.040.0  •  Subject to technical modification