Other Countries
Pricelist request
Copyright
Group Head Quarters • English
Ethics Policy
Home • Products • FansAxial fans • AWFN
I06  •  Axial wall fansdownloads

AWFN

Axial wall fan

Application

  • The AWFN wall fans are suitable for the ventilation of industrial stock farms, greenhouses, garages, gymnasiums, car parks

Composition

  • Supporting frame in drawn steel sheet, with wide rat in aspiration. Protected against the atmospheric agents with epoxy particle painting. With safety guard at the motor side.
  • Airflow type A (from motor to impeller 
  • The axial impeller with profile blades in black plastic material and hub in die-cast aluminium alloy.  
  • Asynchronous motor according to IEC34-IEC72 
  • Protection IP55 – Insulation class F 
  • Supply: 230Vac 1ph 50Hz or 230/400Vac 3ph 50Hz.
  • The motors are suitable for speed regulation by transformer controllers or by frequency inverter.
  • AWFN 200/250  IP32 and IP44, class B

Options

  • Airflow type B (from impeller to motor)
  • Explosion proof version ATEX II 2G IIB T4

 

Accessories

  • Spacer manufactured in metal sheet
  • Impeller protection guard
  • Gravity shutter type VK
  • Transformer speed regulators type BTRN
  • Frequency inverters type ACH

Order example

  • AWFN 4-500T + BTRN-4-4 + VK540
  • AWFN=fan
  • 4= 1400rpm - 6=900rpm
  • BTRN= speed controller
  • VK= backdraught shutter

Articles

Article number Type Diameter [mm] Speed [rpm] Voltage [V]
  I060122200420AWFN 200 4M - TYPE A 200 1400 1 x 230
  I060122200440AWFN 200 4T - TYPE A 200 1400 3 x 400
  I060122250420AWFN 250 4M - TYPE A 250 1400 1 x 230
  I060122250440AWFN 250 4T - TYPE A 250 1400 3 x 400
  I060122315420AWFN 315 4M - TYPE A 315 1400 1 x 230
  I060122315440AWFN 315 4T - TYPE A 315 1400 3 x 400
  I060122355420AWFN 355 4M - TYPE A 355 1400 1 x 230
  I060122355440AWFN 355 4T - TYPE A 355 1400 3 x 400
  I060122400420AWFN 400 4M - TYPE A 400 1400 1 x 230
  I060122400440AWFN 400 4T - TYPE A 400 1400 3 x 400
  I060122450420AWFN 450 4M - TYPE A 450 1400 1 x 230
  I060122450440AWFN 450 4T - TYPE A 450 1400 3 x 400
  I060122500420AWFN 500 4M - TYPE A 500 1400 1 x 230
  I060122500440AWFN 500 4T - TYPE A 500 1400 3 x 400
  I060122500620AWFN 500 6M - TYPE A 500 900 1 x 230
  I060122500640AWFN 500 6T - TYPE A 500 900 3 x 400
  I060122560440AWFN 560 4T - TYPE A 560 1400 3 x 400
  I060122560640AWFN 560 6T - TYPE A 560 900 3 x 400
  I060122630440AWFN 630 4T - TYPE A 630 1400 3 x 400
  I060122630640AWFN 630 6T - TYPE A 630 900 3 x 400
  I060122710440AWFN 710 4T - TYPE A 710 1400 3 x 400
  I060122710640AWFN 710 6T - TYPE A 710 900 3 x 400

Air performance data

Qv [m³/h]

0 Pa

25 Pa

50 Pa

75 Pa

100 Pa

150 Pa

AWFN 4-200

700 230 - - - -

AWFN 4-250

1250 500 - - - -

AWFN 4-315

2250 1850 900 - - -

AWFN 4-355

3400 3000 1600 1400 1050 -

AWFN 4-400

4900 4300 2700 2100 1750 -

AWFN 4-450

6800 6200 5600 3200 2700 -

AWFN 6-500

5800 4900 2100 - - -

AWFN 4-500

9000 8700 8000 7200 6000 3100

AWFN 6-560

7650 6500 3580 2250 - -

AWFN 4-560

12500 11250 11150 10200 9000 4800

AWFN 6-630

9000 7500 5000 3500 2000 -

AWFN 4-630

14000 13000 12000 11000 9000 6000

AWFN 6-710

11250 9500 7700 4600 3300 -
AWFN 4-710 17800 16800 15200 14000 13200 11000

Selection curves

Selection curves

Selection curves

Technical data

U [V] P [kW] I [A]

SCT

tm [°C]

to [°C]

n [rpm] Lpa @ 3m [dB(A)]

AWFN 4-200M

230 0.03 0.33 BTRN-1-S1 50 -10 1400 33

AWFN 4-250M

230 0.07 0.35 BTRN-1-S1 50 -10 1400 39

AWFN 4-315M

230 0.09 1.10 BTRN-1-2 50 -10 1400 48

AWFN 4-355M

230 0.12 1.10 BTRN-1-2 50 -10 1400 57

AWFN 4-400M

230 0.18 1.65 BTRN-1-2 50 -10 1400 55

AWFN 4-450M

230 0.37 3.30 BTRN-1-3 50 -10 1400 61

AWFN 6-500M

230 0.18 0.75 BTRN-1-S1 50 -10 900 53

AWFN 4-500M

230 0.55 4.40 BTRN-1-5 50 -10 1400 63

AWFN 6-560M

230 0.26 2.20 BTRN-1-3 50 -10 900 55

AWFN 4-560M

230 0.75 5.60 BTRN-1-7 50 -10 1400 67

AWFN 4-630M

230 1.10 7.70 - 50 -10 1400 71

AWFN 4-200T

400 0.03 0.16 BTRN-4-2 50 -10 1400 32

AWFN 4-250T

400 0.03 0.16 BTRN-4-2 50 -10 1400 39

AWFN 4-315T

400 0.09 0.40 BTRN-4-2 50 -10 1400 48

AWFN 4-355T

400 0.12 0.45 BTRN-4-2 50 -10 1400 51

AWFN 4-400T

400 0.18 0.60 BTRN-4-2 50 -10 1400 55

AWFN 4-450T

400 0.37 1.20 BTRN-4-2 50 -10 1400 61

AWFN 6-500T

400 0.18 0.75 BTRN-4-2 50 -10 900 53

AWFN 4-500T

400 0.55 1.60 BTRN-4-2 50 -10 1400 63

AWFN 6-560T

400 0.26 1 BTRN-4-2 50 -10 900 55

AWFN 4-560T

400 0.75 2.20 BTRN-4-2 50 -10 1400 67

AWFN 6-630T

400 0.37 1.20 BTRN-4-2 50 -10 900 62

AWFN 4-630T

400 1.10 2.70 - 50 -10 1400 71

AWFN 6-710T

400 0.75 2.40 BTRN-4-2 50 -10 900 65
AWFN 4-710T 400 2.20 5.30 - 50 -10 1400 76

SCT = transformer speed controller

tm = maximum air temperature

to = minimum operating temperature

Lpa = Sound pressure level

Sound pressure level Lpa measured in accordance to DIN 45635 T38

The motorspeed is not adjustable by means of an electronic controller

Dimensions

A [mm]

B [mm]

C [mm]

ØD [mm]

E [mm]

ØG [mm]

kg

AWFN 200

290 250 88 210 240 9

5

AWFN 250

340 300 88 260 240 9

7

AWFN 315

390

350 88 310 280 9 8

AWFN 355

440 400 108 360 320 9 9

AWFN 400

490 450 108 410 320 9 10

AWFN 450

540 500 108 460 340 9 14

AWFN 500

650 600 108 510 365

12

20

AWFN 560

700 630 108 570 365 12 22

AWFN 630

800 730 108 640 385 12 26
AWFN 710 850 800 108 710 440 12 35
I06.012.2  •  Subject to technical modification