Other Countries
Pricelist request
Copyright
Group Head Quarters • English
Ethics Policy
J02  •  Split Console Inverter Indoordownloads

AEHI

Single split console model

Product

  • Indoor unit, Inverter, console model

Application

  • Cooling, heating, ventilating and dehumidifaction of bedrooms, small office rooms, living rooms, small shops, apartments, ...

Function

  • Heat pump, Inverter

Refrigerant

  • R410a

Applicable outdoor units

  • AEH09AA-K3DNA1A/I
  • AEH12AA-K3DNA1A/I
  • AEH18AA-K3DNA1A/I

Articles

Article number Size
  J023301091222type 09
  J023301121222Type 12
  J023301181222Type 18

Specifications

  Item

GEH09AA-K3DNA1A

GEH12AA-K3DNA1A GEH18AA-K3DNA1A

Supply Power

V/Hz/ph

230/50/1

230/50/1

230/50/1

Cooling Capacity (Min~Max)

W

2600(450~3200)

3520(600~3950)

5270(900~5600)

Heating Capacity (Min~Max)

W

3300(450~3750)

4000(600~4700)

5500(900~6600)

Air Flow Volume(SH/H/HM/M/LM/L/S)

m3/h

500/430/410/370/330/280/250

600/520/480/440/400/360/280

650/620/550/500/450/410/320

Dehumidifying Volume

L/h

1

1.20

1.80

EER

W/W

3.42

3.26

3.23

COP

W/W

3.63

3.61

3.62

Fan Type

 

Centrifugal

Centrifugal

Centrifugal

Fan Motor Speed (SH/H/HM/M/LM/L/S)

r/min

650/560/530/480/430/370/320

750/650/600/550/500/450/350

840/800/720/650/580/530/410

Output of Fan Motor

W

20

20

20

Fan Motor RLA

A

0.34

0.34

0.34

Sound Pressure Level (SH/H/M/L/SL)

dB (A)

40/38/36/33/30/26/24

42/40/38/37/35/32/26

48/46/44/41/37/35/32

Sound Power Level (SH/H/M/L/SL)

dB (A)

50/48/46/43/40/36/34

52/50/48/47/45/42/36

58/56/54/51/47/45/42

Dimension (WXHXD)

mm

700x600x215

700x600x215

700x600x215

Net Weight

kg

15

15

15

Application Area

m2

12-18

16-24

23-34

J02.330.1  •  Subject to technical modification
downloads
Requesting information. Please wait a moment...

Requesting information. Please wait a moment...
PRODUCTS