J03  •  Air renewal and purification unit, fresh airdownloads

CPAN-U1

  • CPAN-U ELFOFresh2 is an air renewal and purification unit, full fresh air with return/exhaust and thermodynamic heat recovery, reversible heat pump. It provides consistently clean air, at the right temperature and the right level of humidity, for total wellbeing in the home. At the same time it recovers the energy contained in the exhaust air flow, multiplying it thanks to the heat pump technology and supplying it to the serviced rooms. In this way it reduces the fresh air load and supplies additional capacity, helping to maintain comforable conditions
  • ELFOFresh2 uses an active thermodynamic heat recovery unit, in which the inlet and outlet air flows are separated completely by a steel wall. The heat transfer takes place through the cooling circuit, without the risk of contamination between the two air flows. In traditional enthalpic rotary recovery air units, on the other hand, vapour is exchanged between the indoor discharge air flow and the outdoor fresh air flow, leading to substantial possibilities of contamination
  • ELFOFresh2 rejects the stale air and introduces purified and climate controlled outdoor air. The harmful elements and smells present in the outdoor air or those produced inside the home are eliminated by the efficient filtration system. The electrostatic filter is easy to extract and can be fully restored through washing
  • Airflow rate: from 200 m3/h to 650 m3/h

Application

  • Residential applications

Refrigerant

  • Environmental-friendly refrigerant agent R410A

 

Function

  • Reversible heat pump

Specifications

  • High efficiency summer and winter active thermodynamic heat recovery
  • 80% satisfaction of the building's heating requirement
  • Reduced consumption and simplified system
  • Electronic filtration for effective protection against even the most insidious pollutants (i.e. PM10, bacteria, pollen)
  • Summed dehumidification, ideal for combination with radial cooling
  • Free-Cooling
  • ELFO Control system
  • Hermetic rotary compressors

Accessories

  • Ducted 1.2/3 kW electric heaters
  • Immerse electrode steam humidifier
  • Electronic filter
  • Discharge air filter

Order example

  • CPAN-U 200 (1)- (2)FAS (3)CHIDP1 (4)- (5)-

 

Explanation:

CPAN-U - reversible heat pump

 

200 - size

 

(1) Operation:

- Operation in cooling and heating (Standard)

OHO - Operation in heating-only

 

(2) Filtration:

FAS - Pleated filter G3 (Standard)

FES - Electronic filter 

 

(3) Control systems:

CHIDP1 - HID-P1 thermostat (Standard)

PRELF - ELFOSystem enabled with RS485 Modbus serial port

HIDRS - HID-P1 thermostat and RS485 Modbus serial port

 

(4) Differential pressure switch for filters:

- Not required (Standard)

PSAE - Fresh air filter differential pressure switch

 

(5) Condensate drain pump:

- Not required (Standard)

CDP - Condensate drain pump

Technical data

Sizes 200 300 500 650
A7 (1)
Heating capacity kW 1.82 2.31 3.60 5.02
Total input kW 0.42 0.57 0.79 1.21
COP - 4.33 4.05 4.56 4.15
A-5 (1)
Heating capacity kW 1.87 2.36 3.75 5.12
Total input kW 0.34 0.41 0.63 0.94
COP - 5.50 5.75 5.95 5.45
A-5 (1)
Cooling capacity kW 1.56 2.10 2.96 3.96
Total input kW 0.52 0.67 0.98 1.40
EER - 3.00 3.13 3.02 2.83
A-5 (1)
Cooling capacity kW 1.57 2.02 2.86 3.86
Total input kW 0.55 0.7 1.04 1.45
EER - 2.85 2.89 2.75 2.66
Nominal air flow rate l/s 54 85 136 181
Fan power input (2) W 40 52 90 150
Maximum available static pressure Pa 120 120 120 120
Operating limit in heating mode (3) °C -15 -15 -15 -15
Operating limit in cooling mode (4) °C 40 (38) 40 (38) 40 (38) 40 (38)
Sound pressure level (5) dB(A) 39 41 44 46
Power supply V/Ph/Hz 230/1/50

Notes

Data referred to the following conditions:

All the data provided meets standard EN 14511:2008 and refers to an available head of 50 Pa. When in cooling mode it is possible that the unit is operating at a reduced flow to ensure a specific humidity for the air introduced into the environment in keeping with the setpoint

(1) A7 External air temperature 7°C D.B. / 6°C W.B.; Exhaust air temperature: 20°C D.B. / 15°C W.B.

     A-5 External air temperature -5°C D.B. / -5.4°C W.B.; Exhaust air temperature: 20°C D.B. / 15°C W.B.

     A30 External air temperature 30°C D.B. / 22°C W.B.; Exhaust air temperature: 27°C D.B. / 19°C W.B.

     A35 External air temperature 35°C D.B. / 24°C W.B.; Exhaust air temperature: 27°C D.B. / 19°C W.B.

(2) Capacity referring to operation in heating mode in conditions A-5. Important: the COP and EER already include the fan power and input. This information is provided for the purposes of energy certification programmes. If this information is taken into account, the COP used must be the COP without the fan power input

(3) In places where the outdoor air temperature falls below -5°C for a large number of hours per year, we recommend using EHPCX accessory - ducted heater kit

(4) With RH = 40%; in parentheses, the limit at which a specific humidity of 10.5 g/kg is guaranteed for the air introduced into the environment, with a 50% reduction in the maximum flow

(5) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field coditions

 

Dimensions

200 300 500 650
A mm 803 803 1038 1038
B mm 704 704 792 792
C mm 364 364 423 423
A1 mm 580 580 580 580
B1 mm 300 300 300 300
B2 mm 300 300 300 300
W kg 70 75 95 100

Notes

  • A = Length
  • B = Width
  • C = Height
  • W = Weight
  • For trouble-free operation of the unit it is essential to maintain the clearances in red
  • The above data refer to standard units

Working principles

Notes

A. Air filter

It purifies the fresh air before introducing it into the rooms

B. Internal exchanger

It transfers energy (heat / cool) to the fresh air. Finned direct expansion exchanger with copper tubes and aluminium fins

C. Supply fan

It blows treated air in the rooms. Centrifugal fan powered in direct current directly coupled to the electric motor

D. Compressor

It allows to “move” the heat from the exhaust to the fresh air. Ermetic rotary compressor

E. External exchanger

It recovers energy (heat / cool) from the exhaust air. Finned direct expansion exchanger with copper tubes and aluminium fins

F. Exhaust air fan

It rejects the unhealthy air outdoors. Centrifugal fan powered in direct directly coupled to the electric motor

G. Electrical remote panel

It is possible to remove the electrical panel and make it remote to facilitate the installation

MAIN OPTIONS

1. High-efficiency filtration

The electronic filter (efficiency equivalent to H10) increases the purity of inlet air, reducing the costs of energy used for ventilation

2. Resistance from 1,5 to 3 kW

It allows to maintain a supply temperature next to the comfort temperature without intervening on the air flow decreasing

3. Immersed electrode humidifier

For the outdoor air humidifcation

4. Exhaust air filter

For the recovery coil protection on the exhaust air

J03.900.14  •  Subject to technical modification