J03  •  Water chillerdownloads

WSH-XSC

  • WSH-XSC feature high efficiency, self-adaptation and reliability
  • Capacity: from 195 to 560 kW

Refrigerant

  • R410A

Compressors

  • Scroll

Accessories

  • Rubber antivibration mounts
  • Outdoor installation
  • Shut-off valve on compressor supply and return
  • High and low pressure gauges
  • HydroPack with 2 pumps
  • HydroPack supply side with 2 pumps
  • HydroPack with 2 pumps + 1 in stand-by
  • HydroPack supply side with 2 pumps + 1 in stand-by
  • HydroPack with 3 pumps
  • HydroPack supply side with 3 pumps
  • Connection set exchanger with hydronic group (supply side)
  • Connection set exchanger with hydronic group (user side)
  • Supply side anti-ice electric heaters for hydronic group
  • User side anti-ice electric heaters for hydronic group
  • Steel mesh filter on supply side
  • Steel mesh filter on user side
  • 2-way modulating valve
  • Set point communication with 0-10 V signal
  • Set point communication with 4-20 mA signal
  • Set point communication with fresh air sensor
  • Set point communication according to outdoor enthalpy
  • Phase monitor
  • Shunt capacitors (power factor > 0.9)
  • Soft start
  • CAN/MODBUS serial converter kit
  • CAN/LonWorks serial converter kit
  • Data logger
  • Master-slave operation
  • Free contacts for compressor status
  • Remote control with remote microprocessor control

Technical data

Sizes 65D 70D 75D 80D 85D 90D 100D 110D 115D 120D 135E 150F 165F 180F
Cooling capacity (1) kW 195 207 223 234 251 286 312 334 353 371 406 440 497 560
Total input (1) kW 41.5 44.5 47.6 50.3 53.7 59.8 65.4 70.5 75.7 79.6 86.6 94.20 106 120
EER EUROVENT 4.70 4.65 4.68 4.65 4.67 4.78 4.77 4.74 4.66 4.66 4.69 4.67 4.69 4.67
ESEER 6.11 6.15 5.87 6.03 5.88 6.02 5.99 6.15 6.09 6.07 6.10 6.28 6.21 6.24
Heating capacity (2) kW 224 237 257 269 289 327 356 383 407 428 466 506 574 646
Total input (2) kW 51.2 55.0 58.2 61.6 64.9 73.2 79.9 86.6 93.1 98.2 107 115 130 147
COP 4.38 4.31 4.42 4.37 4.45 4.47 4.46 4.42 4.37 4.36 4.36 4.40 4.42 4.39
Number of refrigerant circuits 2
Number and type of compressors 4 SCROLL 5 SCROLL 6 SCROLL
ST Sound pressure level (3) dB(A) 73 74 74 74 74 74 76 76 76 76 76 76 77 77
EN Sound pressure level (3) dB(A) 64 64 65 65 66 66 67 68 68 68 68 68 68 69
Power supply V/Ph/Hz 400/3/50

Notes

Data referred to the following conditions:

(1) Internal exchanger water = 12/7 °C; external exchanger water = 30/35°C

(2) Internal exchanger water = 12/7°C; external exchanger water = 40/45°C

(3) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field coditions

Dimensions

65D 70D 75D 80D 85D 90D 100D 110D 115D 120D 135E 150F 165F 180F

A

mm

2510 2510 2510 2510 2510 2510 2510 2510 2510 2510 2976 2976 2976 2976

B

mm

850 850 850 850 850 850 850 850 850 850 850 850 850 850

C

mm

1890 1890 1890 1890 1890 1890 1890 1890 1890 1890 1890 1890 1890 1890

A1

mm

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

A2

mm

1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500

B1

mm

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

B2

mm

700 700 700 700 700 700 700 700 700 700 700 700 700 700

Notes

  • A = Length
  • B = Width
  • C = Height
  • W = Weight
  • For trouble-free operation of the unit it is essential to maintain the clearances in red