J03  •  Water chillerdownloads

ME

  • The condenserless water chillers of the ME series are units designed for indoor installation to be matched with a remote condenser. These units are particularly suitable for noise-sensitive environments and for resolving problems concerning the space occupied by a packaged chillers. The condenserless water chillers in the ME series have been designed for combination with the air-cooled condensers of the CE series
  • Capacity: from 4.8 to 138 kW

Refrigerant

  • R407C

Compressors

  • Scroll

Accessories

  • Manifold for unit with double exchanger
  • Serial communication module PC/BMS MODBUS for 1 unit (Master)
  • Serial communication module PC/BMS MODBUS from 2 to 254 units (Slave)
  • Steel mesh filter on water side
  • Daily and weekly programming clock
  • Phase monitor
  • Remote control with remote microprocessor control
  • Supply voltage 400/3/50 without neutral (series 17-21)
  • Liquid line solenoid valve

Technical data

Sizes 17 21 25 31 41 51 61 71 81 91 101 121
Cooling capacity (1) kW 4.79 5.99 7.28 8.39 10.8 12.8 15.3 17.1 18.8 22.5 26.3 32.3
Total input (1) kW 1.49 1.91 2.23 2.64 3.12 3.86 4.47 5.07 5.84 7.12 8.19 10.1
EER EUROVENT - 3.21 3.14 3.26 3.18 3.46 3.32 3.42 3.37 3.22 3.16 3.21 3.20
Number of refrigerant circuits 1
Number and type of compressors 1 SCROLL
Sound pressure level (2) dB(A) 49 49 49 49 50 50 50 50 59 59 60 62
Power supply V/Ph/Hz 230/1/50 400/3/50
Sizes 102 142 162 182 202 222 242 292 322 362 422
Cooling capacity (1) kW 25.7 34.2 37.5 45.1 52.5 58.5 64.5 82.1 96.9 113 138
Total input (1) kW 7.69 10.1 11.7 14.3 16.4 18.3 20.1 24.9 29.4 33.9 41.6
EER EUROVENT - 3.34 3.39 3.21 3.15 3.20 3.20 3.21 3.30 3.30 3.33 3.32
Number of refrigerant circuits 2
Number and type of compressors 2 SCROLL
Sound pressure level (2) dB(A) 53 53 62 62 63 64 65 66 66 66 66
Power supply V/Ph/Hz 400/3/50

Notes

Data referred to the following conditions:

(1) Internal exchanger water =  12/7°C; Dew point = 50°C

(2) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field coditions

Dimensions

17 21 25 31 41 51 61 71 81 91 101 121
A

mm

402 402 402 402 402 402 402 402 402 402 402 402
B

mm

487 487 487 487 602 602 602 602 602 602 602 602
C

mm

790 790 790 790 790 790 790 790 915 915 915 915
A1

mm

300 300 300 300 300 300 300 300 300 300 300 300
A2

mm

300 300 300 300 300 300 300 300 300 300 300 300
B1

mm

500 500 500 500 500 500 500 500 500 500 500 500
B2

mm

300 300 300 300 300 300 300 300 300 300 300 300
W

kg

77 80 85 87 91 92 93 93 113 113 113 119
102 142 162 182 202 222 242 292 322 362 422
A

mm

802 802 802 802 802 802 802 580 580 580 580
B

mm

602 602 602 602 602 602 602 1062 1062 1062 1062
C

mm

790 790 915 915 915 915 915 1538 1538 1538 1538
A1

mm

300 300 300 300 300 300 300 300 300 300 300
A2

mm

300 300 300 300 300 300 300 300 300 300 300
B1

mm

500 500 500 500 500 500 500 500 500 500 500
B2

mm

300 300 300 300 300 300 300 300 300 300 300
W

kg

158 193 232 232 239 245 250 410 445 468 520

Notes

  • A = Length
  • B = Width
  • C = Height
  • W = Weight
  • For trouble-free operation of the unit it is essential to maintain the clearances in red