Other Countries
Pricelist request
Copyright
Group Head Quarters • English
Ethics Policy
J10  •  Design air curtainsdownloads

ACA-D

Design air curtain with electrical heater for door heights up to 6 meter especially invented to become a part of a fashionable interior, this thanks to his elegant shape and design. The integrated tube-lamp underlines the whole design.

Adjustable lamellas allow required air-flow setting. All the electric connection are hidden in the mounting foot (standard length 1 m, also on request in 1.5 m or 2 m). The air curtain is standard delivered with a comfort regulation and makes it possible to control the air curtain with a PID regulation, to make this regulation possible there is standard delivered with the air curtain an outdoor sensor. The internal diagnostic systems that is integrated in the comfort control, controls the good working of the air curtain and gives back the error codes when needed.

Specifications

  • Supply voltage: 400 V AC - 3 ph, Modulated heating steps

Application

  • Shop
  • Bars
  • Offices
  • Hotel entrance halls
  • Storage spaces

Material

  • Steel casing and mounting foot painted in silver metallic
  • Remote control with LCD display in PVC electric box for surface mounting

Colour

  • Silver metalic

Mounting

  • Ceiling

Text for tender

The air curtain shall have adjustable exhaust lamellas. The fan shall be controlled with a 3-speed remote control that is provided with the air curtain. The regulation of the air curtain shall be done with a comfort control with LCD display that is delivered with the air curtain and allows a PID regulation of the electric heater. If the air curtain is one with electrical heater, the electric heater is from the type wire heater. The air curtain shall also have an integrated tube-lamp. The casing will be in steel coated in silver metallic or any other RAL colour on request.

Technical data

Q P V I Lpa - 3m

[m3/h]

[kW] [V] [A] [dB(A)] [kg]
ACA-D-100E 2700 9.5 400 15.8 54 33
ACA-D-150E 4050 15 400 24.7 56.5 45
ACA-D-200E 5400 19 400 31.5 58 58
ACA-D-100W 2450 16.4/20.1* 230 1.8 53 35
ACA-D-150W 3700 25.8/31.6* 230 2.7 55.5 48
ACA-D-200W 4900 35.1/42.9* 230 3.6 57 63
ACA-D-100S 2800 - 230 2 54 30
ACA-D-150S 4200 - 230 3 56.5 41
ACA-D-200S 5600 - 230 4 58 53

Q P V I Lpa - 3m

[m3/h]

[kW] [V] [A] [dB(A)] [kg]
ACA-D-100E 2700 9.5 400 15.8 54 33
ACA-D-150E 4050 15 400 24.7 56.5 45
ACA-D-200E 5400 19 400 31.5 58 58
ACA-D-100W 2450 16.4/20.1* 230 1.8 53 35
ACA-D-150W 3700 25.8/31.6* 230 2.7 55.5 48
ACA-D-200W 4900 35.1/42.9* 230 3.6 57 63
ACA-D-100S 2800 - 230 2 54 30
ACA-D-150S 4200 - 230 3 56.5 41
ACA-D-200S 5600 - 230 4 58 53

  • * Values measured at inlet air temperature + 18°C and temperature drop 90/70°C / 80/60°C

Order example

ACA-D 100 E

 

Explanation

ACA-D = Design air curtain with wired remote control

100 = Length in cm, 150, 200

E = electric heater; W = water heater; S = without heater

Parameters water exchanger

Type

Temperature drop 80/60°C

Temperature drop 90/70°C

Waterconnection

Δt*

Water flow Dp water

Δt*

Water flow Dp water

[°C] [l/s] [kPa] [°C] [l/s] [kPa]

ACA-D-100W

3/4"

38.1 0.2 2.06

42.8

0.25 2.84

ACA-D-150W

3/4"

39.2

0.31

2.45

44

0.39 3.33

ACA-D-200W

3/4"

39.6 0.43

2.25

44.4 0.53 3.04

* Temperature of intake air +18°C

Parameters electric heater

Δt*

I
[°C] [A]
ACA-D-100E 10.6 13.7
ACA-D-150E 11.1 21.7
ACA-D-200E 10.6 27.4

* Temperature of intake air +18°C

Dimensions

A B C
[mm] [mm] [mm]
ACA-D-100 1050 520 350
ACA-D-150 1600 520 350
ACA-D-200 2030 520 350
J10.110.5  •  Subject to technical modification